Top Innovator: SAIC Helps NASA Create Faster Spectrometer System

Fourier transform spectroscopy (FTS) can be used to measure a host of environmental conditions, including water, atmospheric, gaseous, particulate, and thermal pollution. Thanks to a joint effort of NASA’s Langley Research Center and Science Applications International Corporation (SAIC), collecting the data from FTS measurements may become easier.

SAIC and Langley developed a faster, more accurate, and less expensive method of processing measurement data from infrared spectroscopy for materials and chemistry studies. The method requires less hardware and captures data at any wavelength. This method improves upon existing methods — it is simpler, more accurate, faster, and less expensive than previous methods. It also uses less hardware and can be used with all wavelengths.

In conventional measurements, a reference laser signal runs through the device, is guided to a separate detector, and triggers capture of the spectral signal. This old method restricts usable wavelengths to less than half the frequency of the laser. As part of a modification that does away with this limitation, a mirror slides along the device at a constant speed during the scan. Unavoidable velocity variations require linearization or resampling with respect to a known reference for which a metrology laser is employed. The laser is guided as before, but the signal is sent to a different detector where the timing information is stored and used to mathematically correct the velocity of the original signal in post-processing. The problem with this approach is that extra hardware, post-processing, and tuning are required, and the process can be somewhat difficult to perform.

Langley’s method digitizes the laser signal in a separate channel along with spectra data, which eliminates the hardware required in previous methods. It then demodulates the laser signal with a synthetic quadrature phase detector combined with phase tracking to derive the proper slide position for each data point. This method only requires inexpensive 24-bit audio digitizers, rather than the more expensive event counters of the previous method. The new method does not require tuning and high-resolution data can be obtained at any wavelength.

For its continued effort in helping federal agencies solve complex technical challenges that improve efficiency and results, SAIC has earned a Market Connections Top Innovator Commendation.

Share

© 2017 Market Connections, Inc.  All rights reserved. Privacy Policy